05TA Service Manual
SERVICE OPERATIONS
7/24/13
9-16
Thawing Timer.
The thawing timer governs the ice thawing period. It is located inside the control
panel (FIGURE 6-2). It is started by action of the freezer pressure switch (FPS) which energizes the
“CR” relay. This timer is set prior to shipment for approximately a two minute period.
FIGURE 9-14A
Thawing Timer
Set the thawing period for at least 30 seconds longer than the time required to harvest the entire
discharge of ice. If it should be necessary to change the setting of the timer, turn the adjustment
screw clockwise to increase the time or counter-clockwise to decrease the time. Check thaw time
after each adjustment.
FIGURE 9-14B
Thawing Timer Wiring
Syrelec Timer (Orange)
Light
indicates
timer is timing
Light
indicates
timer has
timed out
Time Base:
Set to “min”
Scale: Set to
“X1”
Crouzet Timer (White)
Light flashing when timing
Light Solid when timed out
Range: Set
to “1-10
min”
Voltage rating: 24-240V
Allen Bradley Timer (White)
0
2
4
6
8
10
12
RANGE
UNIT
POWER
UP
Min
Range: Set to
“0 to 12”
Time Range
adjustment
0 - 1.2
0 - 3
0 - 12
0 - 30
Power Light (green)
Light blinks while "timing"
Light solid when "timed
out"
Up Light (red)
Light off while "timing"
Light solid when "timed
Unit adjustment
sec
min
hrs
10h
Units: Set to “min”
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...