INSTALLING YOUR TUBE-ICE
®
MACHINE
3/21/14
3-9
Ice Machine Model
05TA (Standard)
05TA (High Ambient)
Electrical Frequency, Hz.
60/50
60/50
Recommended Condenser
BNHS02A015(8)
BNHS02A015(12)
Total Heat Rejection (BTU/hr)
192,000 / 176,600
229,500 / 211,100
Fans:
Number
HP, Each
Total CFM
2
1 1/2
19,800/18,216
2
1 1/2
19,800/18,216
Full Load Amps (FLA):
3 ph., 208/230V., 60 hz.
3 ph., 460V., 60 hz.
3 ph., 190V., 50 hz.
3 ph., 380V., 50 hz.
14.0
7.0
14.0
7.0
Weight, lbs.:
Net
Shipping
Operating (Maximum flooded) R-404a
625
805
680
635
815
690
Condenser Dimensions, inches
A (Width)
B (Length)
C (Height)
D (Leg centerline)
E (Leg centerline)
F (Clearance below)
45.46”
127”
49.15”
38”
106.15”
20.5”
Recommended Line Sizes, OD
Liquid
All lengths and orientations
Discharge Gas
Vertical Up, all lengths
Horiz. or Down, < 75 ft.
Horiz. or Down > 75 ft.
1 1/8”
1 3/8”
1 3/8”
1 5/8”
Connections at Condenser:
Liquid (ODC)
Discharge Gas (ODC)
1 1/8”
1 5/8”
Connections at Ice Machine:
Liquid (ODC)
Discharge Gas (ODC)
1 1/8”
1 3/8”
TABLE 3-4
Air-Cooled Condenser Data
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...