05TA Capacity Ratings
Makeup
Water Temp.
(°F)
Rated Capacity (lbs/day)
60Hz
50Hz
1"
1 1/4"
1 1/2"
1"
1 1/4"
1 1/2"
40
11630
11800
11100
11360
10315
9700
41
11645
11720
11060
11290
10245
9665
42
11655
11640
11020
11220
10175
9630
43
11670
11560
10980
11150
10105
9595
44
11675
11480
10940
11080
10035
9560
45
11680
11400
10900
11010
9965
9525
46
11685
11360
10860
10975
9930
9490
47
11685
11320
10820
10940
9895
9455
48
11680
11280
10780
10910
9860
9420
49
11680
11240
10740
10875
9825
9385
50
11670
11200
10700
10840
9790
9350
51
11660
11160
10660
10770
9755
9315
52
11650
11120
10620
10700
9720
9280
53
11635
11080
10580
10630
9685
9245
54
11615
11040
10540
10560
9649
9210
55
11595
11000
10500
10490
9615
9175
56
11575
10960
10420
10455
9580
9105
57
11550
10920
10340
10415
9545
9035
58
11525
10880
10260
10385
9510
8965
59
11495
10840
10180
10350
9475
8895
60
11460
10800
10100
10315
9440
8825
61
11425
10720
10060
10245
9370
8790
62
11390
10640
10020
10175
9300
8755
63
11350
10560
9980
10105
9230
8725
64
11305
10480
9940
10035
9160
8690
65
11260
10400
9900
9965
9090
8655
66
11215
10320
9820
9895
9020
8590
67
11165
10240
9740
9825
8950
8515
68
11110
10160
9660
9755
8880
8445
69
11055
10080
9580
9685
8810
8375
70
11000
10000
9500
9615
8740
8305
71
10935
9920
9420
9545
8670
8235
72
10875
9840
9340
9475
8600
8165
73
10810
9760
9260
9405
8530
8095
74
10740
9680
9180
9335
8460
8025
75
10670
9600
9100
9265
8390
7955
76
10600
9520
9020
9195
8320
7885
77
10525
9440
8940
9125
8250
7815
78
10445
9360
8860
9055
8180
7745
79
10365
9280
8780
8985
8110
7675
80
10285
9200
8700
8915
8040
7605
81
10195
9120
8620
8810
7970
7535
82
10110
9040
8540
8705
7900
7465
83
10020
8960
8460
8600
7830
7395
84
9925
8880
8380
8495
7760
7325
85
9830
8800
8300
8390
7690
7255
86
9730
8720
8220
8320
7620
7185
87
9630
8640
8140
8250
7550
7115
88
9530
8560
8060
8180
7480
7045
89
9425
8480
7980
8110
7410
6975
90
9315
8400
7900
8040
7340
6905
Capacity rating based on 70°F ambient condition, 100°F Condensing Temperature, making cylinder ice.
For Crushed ice capacity, multiply cylinder ice capacity by 1.04. Capacity rating is average for the model. Individual machines may vary up to 5% above or below.
Capacity rating is for clear ice production with makeup water containing no more than 200ppm total dissolved solids.
Note: Both 50hz & 60hz machines use the same compressor.
Table 11-3
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...