05TA Service Manual
SERVICE OPERATIONS
7/24/13
9-15
Circulating Water Pump Motor
. The motor bearings are prelubricated and sealed. They require
no further lubrication. The pump should operate with the water level above the impeller housing.
The pump is equipped with a mechanical seal that is self-adjusting and requires no lubrication.
However, the pump should not be operated unless circulating water. The pump manufacturer
recommends that a mechanical seal be kept as a spare. When ordering a seal, specify pump size,
type, serial number, and manufacturer’s name as indicated on the nameplate.
FIGURE 9-12
Water Pump
Cutter Gear Reducer.
The oil level for the gear reducer should be checked if there is evidence of a
leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W
cylinder oil or equal. Change oil once a year.
The motor bearings are prelubricated and require no further lubrication. For additional information,
refer to manufacturer’s instructions.
Note: Ventless gear reducer used after August 2010
FIGURE 9-13
Gear Reducer
Gear Reducer (10:1)
Part #:
Replacement food grade oil:
Part #: 19T3020C01
Texaco Cygnus 220
Oil Capacity: 8 ounces
Pump Discharge (1 1/2” FPT)
Pump Suction (2” FPT)
Seal Kit Part #:
Gear Reducer (5:1)
Crushed Ice Only
Part #:
Vent
Plug
Drain Plug
Oil Level Plug
Vent
Plug
Summary of Contents for P118F/HE100
Page 4: ...Vogt Tube Ice Machines Installation Service Manual and Parts Catalog 12A4171M06 05TA Model ...
Page 10: ...05TA Service Manual TABLE OF CONTENTS vi ...
Page 20: ...05TA Service Manual INTRODUCTION 7 19 13 1 10 ...
Page 40: ...05TA Service Manual INSTALLING YOUR TUBE ICE MACHINE 3 7 14 3 18 BLANK PAGE ...
Page 50: ...5 6 5TA Service Manual START UP AND OPERATION 7 19 13 Blank page ...
Page 106: ...05TA Service Manual SERVICE OPERATIONS 3 10 14 9 28 Blank ...
Page 114: ...Blank page ...
Page 115: ...05TA Service Manual TABLES CHARTS 3 10 14 11 1 11 Tables Charts ...