DHS-E Description
3-5
Figure 3-2: Firmware Caution
Figure 3-3: 3 x 8 Module
Although all existing 3 x 8 boards can be used when upgrading an existing DHS system,
some pre-qualification must be performed. This pre-qualification will prevent noise
problems on stations that can result from a firmware incompatibility issue. This issue can
be corrected by obtaining the correct firmware from Vodavi (refer to
Figure 3-2: Firmware
Caution
for further information).
Firmware
MFG Name
TEC9352
TC5649.1XXXX
LEGEND
XXXX= The firmware version. Once this
number is obtained, compare it to the
following to determine compatibility:
95xx-9736 (OK to install as is).
n
9737-9749 Must replace firmware with
n
9750 version (order PNSP7021-00).
n
9750 & above (OK to install as is).