Call Handling Configuration
6-25
Programmable Range
DISA data fields:
ACCESS CODE = Range 1-24
DISA Lines
DHS
= 1-12 programmable range
DISA Lines
DHS-E
= 1-18 programmable range
DISA DAY COS = Range 0-7
DISA NITE COS = Range 0-7
SERVICE = Never/day/nite/always
TALK TIME = 1/2/3/5/10/15 minutes
EXT Call Forward (ECF)
Description
One CO line in the system may be designated as the External Call Forward (ECF) CO line.
When this CO line rings it is automatically answered by the system and routed to another
CO line where a predetermined telephone number is dialed. These two lines are
connected together in a conference and allowed to remain connected for the duration of
the TALK TIME. ECF programming has four data fields:
INCOMING
–
Is the CO line to be answered by the system.
OUTGOING
–
The CO line to be used by the system for the outgoing call.
SERVICE
–
Setting that allows the feature to operate only during certain system
modes of operation.
TALK TIME – The preset time limit of the ECF call. ECF may be disconnected prior to
the expiration of the TALK TIME by the remote party by dialing [0] + [#] at any time
during the ECF call, or [0] + [
✳
] to extend it.
Default
The
DHS/DHS-E
default settings of associated ECF data fields are:
INCOMING
DHS
= None
INCOMING
DHS-E
= None
SERVICE = Never
TALK TIME = 1
Programmable Range
ECF data fields:
INCOMING
DHS
= 0-12
INCOMING
DHS-E
= 700-718
SERVICE = Never/day/nite/always
TALK TIME = 1/2/3/5/10/15 minutes.
DHS requires the Option Module for correct operation of this Feature.
Summary of Contents for Starplus DHS
Page 17: ......
Page 21: ...1 4 Toll Fraud and DISA Disclaimer...
Page 23: ......
Page 79: ...2 56 Feature Upgrade Procedure...
Page 81: ......
Page 121: ......
Page 227: ......
Page 249: ......
Page 293: ......
Page 303: ......
Page 326: ...B Part Numbers...
Page 327: ......
Page 329: ...B 2...
Page 337: ...xx January 2000 Index...