2-27
Cautionary Steps
To reduce the risk of fire or injury to persons, read and follow these tips:
Use only the following type and size battery(ies) listed here as the maximum battery
type and size: 24vdc, 40 AH.
Do not dispose of any battery(ies) in a fire, the cell may explode. Check with local
codes for possible special disposal instructions.
Do not open or mutilate the battery(ies). Released electrolyte is corrosive and may
cause damage to the eyes or skin. It may be toxic if swallowed.
Exercise care in handling batteries in order not to short the battery with conducting
materials such as rings, bracelets, and keys. The battery or conductor may overheat
and cause burns.
Charge the battery(ies) provided with or identified for use with this product only in
accordance with the instructions and limitations specified in this manual.
Observe proper polarity orientation between the battery(ies) and battery charger.
Do not mix old and new batteries in this product (applies to products employing
more than one user replaceable secondary battery).
Do not mix batteries of different sizes or from different manufacturers in this product
(applies to products employing more than one user-replaceable, secondary battery).
4. KSU Installation
The KSU is designed for wall mounting only. The KSU should NOT be mounted directly on
a masonry surface. If the KSU is to be mounted on a masonry surface, a wooden
backboard of sufficient size should be attached to the wall and the KSU mounted on the
backboard.
1. Using the mounting template as a guide, mark the 2 mounting screws locations on
the MDF backboard.
2. Pre-drill 2 screw holes and install 2 pan-head No. 10 screws into the backboard. The
screw heads should protrude about 1/4-in. from the backboard plywood surface.
3. Lift the KSU over the 2 screws allowing the screws to extend into the KSU slotted
mounting holes. As the KSU is allowed to rest in place on the mounting screws it will
slip over the screw shanks until the top of the slot is reached. Properly installed, the
Table 2-11: Battery Sizing Chart
Configuration
Battery Power (Hr)
12 AH
20 AH
40 AH
3 x 8
3.5
4.5
8
6 x 16
2
3.5
7
9 x 24
1.5
2.5
4
Summary of Contents for Starplus DHS
Page 17: ......
Page 21: ...1 4 Toll Fraud and DISA Disclaimer...
Page 23: ......
Page 79: ...2 56 Feature Upgrade Procedure...
Page 81: ......
Page 121: ......
Page 227: ......
Page 249: ......
Page 293: ......
Page 303: ......
Page 326: ...B Part Numbers...
Page 327: ......
Page 329: ...B 2...
Page 337: ...xx January 2000 Index...