3-22
DHS-E Installation
Figure 3-5: 3 x 8 Module
5. Terminating Connections
3 x 8 Module(s)
1. The CO line connections (as well as station connections) are made to the 3 x 8 Module
via the male 25-pair connector located along the edge of the installed module (refer
to
Table 3-12
).
2. Once the 25-pair cable is terminated on an industry standard 66M1-50 block, cross-
connect (jumper wire) should be used to extend the CO line pair from the terminal
block to the Telco Demarcation block. Plan to use at least one pair of bridging clips for
each CO line connected so that service of any one specific CO line is simplified.