DHS Technical Specification Tables
2-13
DHS Technical Specification Tables
Table 2-2: Digital Hybrid System Capacities
Component
Description
System Programming Memory Protection
300 Hours on a fully-charged battery (internal
Nicad/Nimh battery requires 14 continuous-
powered hours of system operation to
become fully charged.)
Ports:
CO/PBX/Centrex Lines
12 (Note: 16 stations max. with this
configuration.)
Digital Stations
24 (Note: 9 CO lines max. with this
configuration.)
Standard SLTs
46 (Note: one digital port must be reserved
for digital station operation. One digital
station port is used for every 2 SLT ports
required.)
DSS Console
12 (Note: one for each digital station.)
DTMF Receivers:
2-Port CO Module
2 (One for each SLT port)
2-Port Analog Expansion
2 (One for each SLT port)
Option Module
2 (Shared for advanced call processing system
features; DISA, ECF)
DTMF Senders
Unlimited. (DTMF signal generation is derived
from the core system tone resource. Tone
combinations are available as needed.)
Tone Detectors (used to monitor call progress
tones: Busy Tone, Ring-back Tone, etc.)
2 (Shared for advanced call processing system
features; DISA, ECF, ABR. etc.)
Located on the Option Module
Contacts
1 LBC contact is available via the Option
Module.
Conference Circuits
Four-party conference circuits (8 per system).
DISA Circuits
Any number of CO lines may be programmed
for DISA operation.
Summary of Contents for Starplus DHS
Page 17: ......
Page 21: ...1 4 Toll Fraud and DISA Disclaimer...
Page 23: ......
Page 79: ...2 56 Feature Upgrade Procedure...
Page 81: ......
Page 121: ......
Page 227: ......
Page 249: ......
Page 293: ......
Page 303: ......
Page 326: ...B Part Numbers...
Page 327: ......
Page 329: ...B 2...
Page 337: ...xx January 2000 Index...