9
Components
System scheme (parameter 7000)
0
1
2
3
4
5
6
Heating circuit
A1
–
X
X
–
–
X
X
M2
–
–
–
X
X
X
X
DHW cylinder
X
–
X
–
X
–
X
Heating water buffer cylinder
–
0
0
X
X
X
X
External heat source
–
0
*1
0
*1
0
0
0
0
Solar thermal system
0
–
0
–
0
–
0
Cooling
A1
0
0
0
0
M2
0
0
0
0
Sep. cooling circuit
0
0
0
0
0
0
0
X Selected component.
0
The component can be added.
System example 1, ID: 4605169_1005_01
Setting system scheme 6
■ Internal unit of heat pump type AWS
with or without instantaneous heating
water heater
■ 1 radiator heating circuit without mixer
(A1)
■ 1 underfloor heating circuit with mixer
(M2)
■ DHW heating
■ External heat source
■ Heating water buffer cylinder
Note
This scheme is a basic example without
shut-off valves or safety equipment. This
does not replace the local technical engi-
neering task.