16
Required parameters
Parameter
Setting
"System definition"
■
"System scheme 7000"
"6"
"External heat source"
■
"Enable external heat source 7B00"
"1"
■
"Enable external heat source for DHW heating
7B0D"
"1"
DHW heating:
"Time program DHW"
Set time program (see oper-
ating instructions)
"Time prog. DHW circ."
(if a DHW circulation pump is installed)
Set time program (see oper-
ating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
■
"Enable electric heaters for DHW heating 6015"
"1"
Instantaneous heating water heater
(if installed):
"Electr booster heater"
■
"Enable instantaneous heating water heater
7900"
"1"
■
"Enable instant. heating water heater for central
heating 7902"
"0"
Remote controls
(if installed):
"Heating circuit 1"
■
"Remote control 2003"
"1"
"Heating circuit 2"
■
"Remote control 3003"
"1"
To call up
"Coding level 1"
for setting
the parameters, see the commissioning
assistant on page 78 and page 80.
System example 2, ID: 4605170_1005_01
Setting system scheme 6
■ Internal unit of heat pump
type AWS-AC with instantaneous
heating water heater
■ 1 radiator heating circuit without mixer
(A1)
■ 1 underfloor heating circuit with mixer
(M2)
■ DHW heating
■ External heat source
■ Heating water buffer cylinder
■ Cooling on heating circuit M2 (on-site)
with active cooling function
Preparing for installation
System example 1, ID: 4605169_1005_01
(cont.)
5724 152 GB
Summary of Contents for AWS 104
Page 5: ...5 Certificates Declaration of conformity 119 Keyword index 120 Index Index cont 5724 152 GB...