29
3.
4.
2.
4x
Example AWS/AWS-AC 104
2.
Push the connection bracket for the
condensate line at the bottom of the
appliance into one of the openings.
3.
Push plugs into the other opening.
4.
Secure the external unit on the on-
site substructure.
Wall mounting
Install with a mounting panel set for wall
mounting (accessory).
Separate installation instructions
Note
Consider the wind loads when installing
the unit on external walls or on roofs.
Connecting the condensate line
Secure the condensate line (on-site,
7
16 mm) to the connection bracket.
■ Route the line with a slope; prevent
counter-slopes.
■ Connect the line to the drain network.
■ Ensure the condensate can drain off
freely and install a resistance heater
(on-site), if required.
Installation sequence
Installing the external unit
(cont.)
5724 152 GB
Installation