18
Floorstanding installation with support; line entry
below ground level
K
835
1100
3000
B
A
F
300
702
H
E
L
400
G
C
Fig. 11
A
Ground
B
Pathway, patio
C
Refrigerant lines
E
Indoor/outdoor unit bus cable and outdoor unit
power cable
F
Openings in the base plate for free drainage of
condensate
G
Supports for floorstanding installation (accesso-
ries)
H
Foundation strip
K
Frost protection for foundations (compacted
crushed stone, e.g. 0 to 32/56 mm); thickness of
layer subject to local requirements and building
regulations
L
DN 125 conduit with cover and 3 x 30° pipe bends;
sealing of line entry with end collar
Installing an outdoor unit on foundations
A
B
C
D
1.
4x
4x
2.
Fig. 12
A
Supports for floorstanding installation (accesso-
ries)
B
Gravel bed as condensate soakaway
C
Concrete foundations (see technical guide)
D
DN 100 KG conduit (only for line entry below
ground level)
Note
We recommend letting condensate drain away
freely
(without a condensate pipe).
Wall mounting
Installation should
only
be performed with the bracket
set for wall mounting (accessories).
Separate installation instructions
Installation sequence
Installing the outdoor unit
(cont.)
5790 931 GB
Installation