Heating circuit 2
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Standard room temperature"
3000
200 (
≙
20 °C)
"Reduced room temperature"
3001
160 (
≙
16 °C)
"Remote control"
3003
0
"Room temperature control"
3005
0 Without remote
control
2 With remote con-
trol
"Heating curve level"
3006
0 (
≙
0 K)
"Heating curve slope"
3007
6 (
≙
0.6)
"Influence room temperature hook-up"
300A
10
"Room temperature hook-up"
300B
0
"Max. flow temperature heating circuit"
300E
400 (
≙
40 °C)
"Runtime mixer heating circ"
3015
Never adjust
"Room temperature in party mode"
3022
200 (
≙
20 °C)
Heating circuit 3
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Standard room temperature"
4000
200 (
≙
20 °C)
"Reduced room temperature"
4001
200 (
≙
20 °C)
"Remote control"
4003
0
"Room temperature control"
4005
0 Without remote
control
2 With remote con-
trol
"Heating curve level"
4006
0 (
≙
0 K)
"Heating curve slope"
4007
6 (
≙
0.6)
"Influence room temperature hook-up"
400A
10
"Room temperature hook-up"
400B
0
"Max. flow temperature heating circuit"
400E
400 (
≙
40 °C)
"Runtime mixer heating circ"
4015
Never adjust
"Room temperature in party mode"
4022
160 (
≙
16 °C)