130
Electric booster heater
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Enable instantaneous heating water
heater"
7900
1
"Enable electric heaters for DHW heat-
ing"
7901
0
"Enable instant. heating water heater for
central heating"
7902
0
"Start delay instantaneous heating water
heater"
7905
30 min
"Max. output instantaneous heating wa-
ter heater"
7907
3
"Output for instant. heating water heater
at power-OFF"
790A
0
"Dual mode temp. instant. heating water
heater"
790B
500 (
≙
50 °C)
Internal hydraulics
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Heat pump for drying a building"
7300
0
"Time program for screed drying"
7303
0
"Set flow temperature for external de-
mand, cooling"
730A
Never adjust
"Set flow temperature for external de-
mand"
730C
500 (
≙
50 °C)
"Start threshold"
730E
300 (
≙
30 K*min)
"Compressor performance at min. out-
side temperature"
730F
50 %
"Compressor performance at max. out-
side temperature"
7310
20 %
"Cycle rate heating circuit pumps"
7319
0
"Starting time high efficiency circulation
pump"
7365
Never adjust
"Screed program start day"
7378
1
"Screed program end day"
7379
31
Primary source
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
"Primary source ctrl strategy"
7401
Never adjust
Commissioning/service reports
Control parameter report
(cont.)
5790 931 GB
Appendix