17
Floorstanding installation with support; line entry above ground level
3000
B
A
G
200
F
300
K
835
1100
H
702
3000
B
A
G
200
F
300
K
835
1100
H
702
C
E
D
C
D
E
Fig. 10
A
Ground
B
Pathway, patio
C
Pipe bends for vibration compensation in refriger-
ant lines
D
Pipe clips with EPDM lining
E
Indoor/outdoor unit bus cable and outdoor unit
power cable
F
Openings in the base plate for free drainage of
condensate
G
Supports for floorstanding installation (accesso-
ries)
H
Foundation strip
K
Frost protection for foundations (compacted
crushed stone, e.g. 0 to 32/56 mm); thickness of
layer subject to local requirements and building
regulations
Information regarding vibration compensation
(pipe bends
C
)
We recommend installing vibration bends, especially in
pipes < 5 m.
Installation sequence
Installing the outdoor unit
(cont.)
5790 931 GB
Installation