36
Revision 01 - 22.07.2019
resulting values to a file, or immediately send the entire sequence to the CAN-bus. If you press the "Cycle"
button, the sequence will be sent to the CAN-bus in a cycle mode.
When the work with the scanner is finished, it is stopped, the necessary comments are added, you
can save them by clicking the "
" button in the main window of the "CAN-scanner" tab. You can also
download information from a file with *.frames format
At the bottom of the window is the workspace for working with frames. Work can be in the format of
[List] or in the format of [Script]. Switching is carried out by pressing the button on the right, the current
mode is displayed in square brackets on the left.
Work with [List] is constructed as follows:
•
Add frames from the top field to the list using the "
" or "
" button
•
Select the desired frame in the list.
•
Press the "
" button or the space bar for one-time sending, the packet counter will
increase by one
•
Press the “
” button for sending with the specified period, while the packet counter will
increase with each
sending until the “Stop” or “Stop all” button is pressed
Working with [Script] is a little different. If there are several frames in the list, then you can start their
sequential execution by pressing the "
" button, this will be the execution of [Script]. At the same time,
the “
Count
” column takes on a slightly different meaning, here you need to
set the number of repetitions in
advance, after which [Script] will proceed to the next frame. Other control buttons on the right panel also
differ - it becomes possible to repeat the execution of frames cyclically, move frames relative to each other
(raise and lower the list), pause execution at any time.