DALLAS TEMPERATURE SENSORS
Vega MT X CAN monitoring device allows to connect is up to ten Dallas temperature sensors
through 1-Wire interface. Connection scheme is on the picture below. If connected temperature sensor has
three contacts instead of two then you should to close
“
Power
”
with
“
Ground
”
.
For the device to recognize the connection of a new sensor, it is necessary to connect to the device
through the "Configurator" program (see "Settings" part), go to the "Inputs/outputs" tab and select the
"Dallas temperature sensors" setting item.
To distinguish sensors after connection, it is recommended to connect them one at a time. Having
connected the first sensor according to the diagram above, click the "Add sensors" button. An information
window will appear.
Click “OK”
- the sensor number will be added to the free field. After that you can connect the next
sensor in the same way.