54
Revision 01 - 22.07.2019
Some settings of the Vega MT X CAN monitoring device can be managed remotely via SMS
commands. General command format is @PIN:command, where PIN is a four numbers PIN of the device
(S
ee “Security” part
). There are also two information commands, in response to which an SMS message with
information about the device settings.
Command
Format
Example
nosleep
–
not switch to
the sleep mode
@PIN:nosleep
@5555:nosleep
____________
PIN
–
5555
reboot
–
device reboot
@PIN:reboot
@3333:reboot
____________
PIN
–
3333
tofactory - factory reset @PIN:tofactory
@1234:tofactory
____________
PIN
–
1234
bboxclear
–
clear black
box
@PIN:bboxclear
@1234:bboxclear
____________
PIN - 1234
setout
–
set the output
state
@PIN:setoutY=Z
____________
Y
–
output number
Z
–
state (0 or 1)
@4321:setout2=1
____________
PIN
–
4321
Output number
–
2
State - 1
server
–
set the server
address
@PIN:serverY:addr:port
&
protocol
&
period
&
term
inal_addr
____________
Y
–
server number
addr
–
server address
port
–
server port
protocol
–
protocol type:
off
vega
–
engineering server
egts
–
EGTS server
wips
–
Wialon server
ndtp
–
NDTP server
period
–
communication period with server
terminal_addr
–
device address for NDTP or
device ID for EGTS protocol
@2222:server3:193.193.165.1
65:20332
&
wips
&
0
&
90008
____________
PIN
–
2222
Server number
–
3
Server address
–
193.193.165.165
Server port
–
20332
Exchange protocol
–
Wialon
IPS
Communication period
–
0
(constantly in touch)
NDTP address or EGTS
device ID
–
90008