3. Warnings and Precautions
Green Smart User Manual 17
EN
G
LISH
Lasers
The system incorporates Class 1 laser products. The light localizers used in this
product are intended for correct patient positioning and must not be used for any
other purpose.
For maximum safety, advise the patient not to look directly at the laser beam.
While adjusting the patient, ensure that the laser beam is not directed at the patient’s
eyes.
Wavelength: 650 nm, Radiant power: Max. 039 mW
Risk of eye injury!
Do not use this equipment with any other laser sources and do not
make any changes to the settings or processes that are described in
these operating instructions.
Cleaning
Never expose this equipment to liquids, mists or sprays. Exposing this equipment to
liquids may cause an electric shock or otherwise damage the system.
Do not use spray cleaners on this equipment, as this could cause a fire.
During the Operation
Never use this equipment in an environment that is susceptible to explosion.
Do not place flammable materials near this equipment.
Do not operate the PC while the equipment is operating. Failure to comply with this
instruction may result in system malfunction.
Immediately stop imaging if the equipment malfunctions in any way.
If a problem occurs during imaging, press the red Emergency Stop Switch to
immediately stop all moving parts and cut off all power to the equipment’s electrical
components.
Never touch the patient while he or she is touching the SIP/SOP connectors.
The medical electrical equipment or medical electrical system should not be used
adjacent to or stacked with other equipment and that if adjacent or stacked use is
necessary, the medical electrical equipment or medical electrical system should be
observed to verify normal operation in the configuration in which it will be used.
The use of accessories and cables other than those specified, except cables sold by
VATECH of the medical electrical equipment or medical electrical system as
replacement parts for internal components, may result in increased EMISSIONS or
decreased IMMUNITY of EQUIPMENT or SYSTEM.
Summary of Contents for GREEN SMART
Page 1: ...User Manual Version 1 23 English...
Page 2: ......
Page 3: ......
Page 4: ......
Page 52: ...5 Imaging Software Overview 44 Green Smart User Manual Left blank intentionally...
Page 90: ...7 Acquiring PANO Images 82 Green Smart User Manual Left blank intentionally...
Page 110: ...8 Acquiring CEPH Images Optional 102 Green Smart User Manual Left blank intentionally...
Page 126: ...9 Acquiring CBCT Images 118 Green Smart User Manual Left blank intentionally...
Page 134: ...10 Acquiring 3D MODEL Scan Images 126 Green Smart User Manual Left blank intentionally...
Page 142: ...12 Cleaning and Maintenance 134 Green Smart User Manual Left blank intentionally...
Page 144: ...13 Disposing of the Equipment 136 Green Smart User Manual Left blank intentionally...
Page 154: ...14 Technical Specifications 146 Green Smart User Manual Left blank intentionally...
Page 185: ...15 Appendices Green Smart User Manual 177 ENGLISH...
Page 200: ......