Tolerance for New Points
Enter the margin of error that can exist between a new point and a forecast point.
If the new point is within the tolerance limit, it is added to the end of the track
and a new forecast point is created.
If it falls outside the limit, a new track is begun.
Protected Areas for Warning Alert
Specify one or more protected areas.
A warning is generated if a centroid falls within or is forecast to move into a
protected area.
Select
Protected Areas
to see a list of areas. You can toggle choices on or off.
When you exit the list, the names of the selected areas are displayed in the field.
Protected areas are configured with the
Setup
utility. They are constrained to be
rectangles with arbitrary size and orientation angle.
You can configure up to 32 areas. (If you make a change to
Setup
, you must
restart IRIS for the change to take effect.)
TDWR Style
IRIS supports two formats of warning messages. In TDWR format, only the
strongest centroid in the highest priority area is reported along with its strength.
For example:
"MBA 3MF 30K-
, in spoken language: "
Microburst Alert, Three
Mile Final, 30 Knot loss
".
The older IRIS format reports all centroids in all protected areas, for example:
3
MBA warnings at 11:30 in: 3MF, 2MF
. These messages are displayed
at the bottom of the display screen and optionally spoken.
Say Warning
Select this option to have the product generator to verbally signal the warning
message in addition to displaying it as a message.
In the IRIS menu, you must also select
Setup > Enable Speech
.
Make Diagnostic Results
In addition to the
TRACK
product, you can create a thresholded version of the
input product, useful for testing purposes. Unless you encounter a problem with
the
TRACK
product, you can turn this feature off.
Chapter 3 – Configuring IRIS Products
RESTRICTED
91
Summary of Contents for IRIS
Page 1: ...M211319EN H RESTRICTED User Guide IRIS Radar IRIS Product and Display...
Page 12: ...IRIS Product and Display User Guide M211319EN H 10 RESTRICTED...
Page 71: ...Chapter 3 Configuring IRIS Products RESTRICTED 69...
Page 303: ...Figure 103 Typical Spectrum Plot Appendix A Basic Radar Meteorology RESTRICTED 301...
Page 386: ......
Page 392: ......
Page 393: ......
Page 394: ...www vaisala com...