To activate this output, select
Diagnostic
at the bottom of the
DWELL Configuration Menu
.
Note that diagnostic output is produced even if you later disable the target warning, as long
as the diagnostic button is enabled.
The diagnostic outputs are stored as type
USER
products. The naming convention is as
follows:
•
USER: < productname >DAT or TIM
The main output of the
DWELL
product is a product of the same type as the input
product (for example, a
PPI
) for either the input product data type (for example, dBZ)
or time (age).
The diagnostic
USER
product is for the data type that was not selected for the main
output.
For example, if
dBZ
is selected for the main output, the diagnostic
USER
product is for
the time (
TIM
suffix). If time is selected for the main output, the diagnostic
USER
product is for the input data type (
DAT
suffix).
•
USER: < productname >CON
If the contrast filter is enabled, the diagnostic
USER
product with the suffix
CON
shows
the background field. For an example, see
DWELL Algorithm Examples (page 140)
•
USER: < productname >PIL
If target warning is enabled, the diagnostic
USER
product with the suffix
PIL
shows the
"pile" product, that is, the number of target hits per pixel (X4) for the first in the
sequence of the assumed motion vectors (that is, the first trial).
For diagnostic work, the target Warning can be configured to run a single motion
vector so that any speed and direction can be isolated for study.
Chapter 5 – Configuring and Scheduling Optional IRIS Products
RESTRICTED
147
Summary of Contents for IRIS
Page 1: ...M211319EN H RESTRICTED User Guide IRIS Radar IRIS Product and Display...
Page 12: ...IRIS Product and Display User Guide M211319EN H 10 RESTRICTED...
Page 71: ...Chapter 3 Configuring IRIS Products RESTRICTED 69...
Page 303: ...Figure 103 Typical Spectrum Plot Appendix A Basic Radar Meteorology RESTRICTED 301...
Page 386: ......
Page 392: ......
Page 393: ......
Page 394: ...www vaisala com...