Utilimaster Corporation attempts to provide
information that is accurate, complete, and
useful. All information contained in this
manual is based on the latest product infor-
mation available at the time of publication.
However, because of the Utilimaster policy
of continual product improvement, Utilimas-
ter reserves the right to amend the informa-
tion in this document at any time without
prior notice.
This material is confidential and the prop
-
erty of Utilimaster. It is shared with your
company for the sole purpose of helping you
with the operation of the described equip-
ment.
Utilimaster makes no warranty of any kind
with regard to this material, including, but
not limited to, the implied warranties of
merchantability and fitness for a particular
purpose. Utilimaster shall not be liable for
errors contained herein or for incidental or
consequential damages in connection with
the furnishing, performance, or use of this
material.
Utilimaster expressly disclaims all respon-
sibility and liability for the installation, use,
performance, maintenance, and support of
third-party products. Customers are advised
to make their independent evaluation of such
products.
No part of this document may be photo-
copied, reproduced, or translated to another
language without the prior written consent
of Utilimaster.
Utilimaster Corporation attempts to provide
information that is accurate, complete, and
For Assistance Call: 800-237-7806
Visit us at:
www.utilimaster.com
90
Reach—Body Service Manual
E-mail:
Fuel Sending Unit Access Panel
Composite Floor
Located in the cargo area is an access panel for the fuel sending unit. In order to remove panel, the floor
mat around the panel will need to be removed.
Removal
1.
Remove floor mat from around access panel in the center of floor at the rear of the wheel well.
An outline of the access panel should be visible.
2. Use a heat gun on the access panel to aid in the release of the structural adhesive.
3.
Use a flat pry bar to carefully lift up the access panel.
CAUTION: Read and understand ALL methacrylate structural adhesive application instructions and
safety procedures. Effectiveness of the repair can be compromised by environmental conditions
or poor application. Follow structural adhesive manufacturer’s application instructions and
recommendations for cure time. Safety and application instructions provided by manufacturers
always supersede information provided by Utilimaster.
Fuel sending unit access panel under matting
Fuel sending unit access panel
CAUTION: Place a wood block underneath the pry bar to prevent damage to the floor.
Fuel sending unit