Utilimaster Corporation attempts to provide
information that is accurate, complete, and
useful. All information contained in this
manual is based on the latest product infor-
mation available at the time of publication.
However, because of the Utilimaster policy
of continual product improvement, Utilimas-
ter reserves the right to amend the informa-
tion in this document at any time without
prior notice.
This material is confidential and the prop
-
erty of Utilimaster. It is shared with your
company for the sole purpose of helping you
with the operation of the described equip-
ment.
Utilimaster makes no warranty of any kind
with regard to this material, including, but
not limited to, the implied warranties of
merchantability and fitness for a particular
purpose. Utilimaster shall not be liable for
errors contained herein or for incidental or
consequential damages in connection with
the furnishing, performance, or use of this
material.
Utilimaster expressly disclaims all respon-
sibility and liability for the installation, use,
performance, maintenance, and support of
third-party products. Customers are advised
to make their independent evaluation of such
products.
No part of this document may be photo-
copied, reproduced, or translated to another
language without the prior written consent
of Utilimaster.
Utilimaster Corporation attempts to provide
information that is accurate, complete, and
For Assistance Call: 800-237-7806
Visit us at:
www.utilimaster.com
28
Reach—Body Service Manual
E-mail:
Upper Post Removal
This process describes the removal and installation of the header and one side of the upper post
cladding. Repeat the process on the opposite side if necessary.
1. Remove six M6 screws from bottom of header.
2. Remove 12 Allen head screws from top of header.
3. Remove header and lay on top of roof.
4. Disconnect wires to clearance lights.
5. Disconnect camera cable.
6. Remove seven M6 screws in upper post cladding and set aside.
Upper Post Installation
1. Secure upper post cladding with seven M6 screws.
2.
Torque to 7–8 ft•lbs.
3. Set header on roof.
4. Connect cable to camera.
5. Connect wires to clearance lights.
6. Secure bottom of header with six M6 screws.
7.
Torque to 7–8 ft•lbs.
8. Secure top of header with 12 Allen head screws.
CAUTION: Discard ALL used fasteners and replace with new. If using a fastener that does NOT have
preapplied thread lock, apply a medium-grade liquid thread lock.
Header cladding