66/108
Table 6-8: Save Parameters State.
Bit
Value Description
0
1
∼
31
1
0
Support save Parameter.
Reserved
Check ‘SAVE’ part for each object.
6.2.7 Object 1011h: Restore default parameters
Index
Sub
Index Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
1011h 0
Number of
entries
U8
RO
No
No
1
1
Restore
default
parameters
U32
RW
No
No
It requests for the device to restore objects to Default value to store into EEPROM.
Need to input ‘64616F6Ch’ into SubIndex
01h to restore objects to original setting value.
Table 6-9: Definition of Restore Parameters Value.
MSB
LSB
ASCII
‘d’
‘a’
‘o’
‘l’
Hex
64h
61h
6Fh
6Ch
If failed to initialize, SDO communication returns ‘Abort SDO Transfer (abort code: 0606
0000h)’. If inputs
incorrect value, device will not be initi
alized and return ‘Abort SDO Transfer
(abort
code: 0800002xh)’.
Information
the objects’ value will be set to default after
the power cycle.
In case of reading SubIndex 01h, the following values will be returned.
Table 6-10: Restore Parameters State.
Bit
Value Description
0
1
∼
31
1
0
Support Restore Default Parameter.
Reserved
6.2.8 Object 1018h: Identity
Index Sub Index
Name
Type Access Constant Value
1018h 0
Number of entries
U8
RO
4
1
Vendor ID
U32 RO
0000 0CC8h
2
Product code
U32 RO
0001 0001h
3
Revision number
U32 RO
0000 0000h
4
Serial number
U32 RO
0000 0000h