Table 4-1: State transition.
Transition Event
Action
0
Automatic transition after power-
on or reset application.
Drive self-test and/or self initialization
shall be performed.
1
Automatic transition.
Communication shall be activated.
2
Automatic transition
1
or
Shutdown command from control
device.
3
Switch On command from control
device.
4
Enable Operation command from
control device.
The drive function shall be enabled.
5
Disable Operation command from
control device.
The drive function shall be disabled,
motor power shall be switched off.
6
Shutdown command from control
device.
7
Quick Stop or Disable Voltage
command from control device.
8
Shutdown command from control
device.
The drive function shall be disabled,
Motor power shall be switched off.
9
Disable Voltage command from
control device.
The drive function shall be disabled,
Motor power shall be switched off.
10
Quick Stop or Disable Voltage
command from control device.
11
Quick Stop command from
control device.
The quick stop function shall be started.
12
Automatic transition (depends on
the Quick stop option code).
The drive function shall be disabled,
Motor power shall be switched off.
13
Fault signal.
The configured fault reaction function
shall be executed.
14
Automatic transition.
The drive function shall be disabled,
Motor power shall be switched off.
15
Fault Reset command from
control device.
A reset of the fault condition is carried
out.
16
Enable Operation command from
control device (depends on the
Quick stop option code).
The drive function shall be enabled.
1
This transition is configurable. Please refer to Object 2030h: Advanced settings
Sub-Index 2
–
Disable Automatic transition 2.
Each status of functions supported by the controller as follows.