55/108
Figure 4-19: Touch Probe Operation (Bit 1/Bit 9 = 0).
Able to check whether input signal acknowledged through Touch probe status of bit number
1
∼
2, 9
∼
10 (Detected). Acknowledged position value, please check Touch probe 1 positive
value, Touch probe 2 positive value, Touch probe 1 negative value, Touch probe 2 negative
value.
4.7.3.2
Touch Probe Operation: Continuous signal acknowledgment
If the Touch probe function of bit number 1, 9 has set as 1, the Touch probe uses all
acknowledged signals after Enable. Please refer to the Timing chart as follows.
Figure 4-20: Touch Probe Operation (Bit 1/Bit 9 = 1).
Touch probe status of bit number 6
∼
7, 14
∼
15 (Counter) value increases every single of
input signal acknowledgment. (Range of this value is 0
∼
3.) For the frequency of input signal
acknowledgment, please check Touch probe 1 positive edge counter, Touch probe 2 positive
edge counter, Touch probe 1 negative edge counter, Touch probe 2 negative edge counter.