59/108
5.2.4 PDO Mapping
Set Module and PDO Mapping by setting function of Master.
Information
Trial operation explains operation by Profile Position Mode.
Select the Module: ‘Axis (Normal): dynamic select operation mode’.
The name of the Module can be differentiated by each Master.
5.2.5 Set Communication Status
Change EtherCAT State Machine as ‘OP’ status by controlling Master.
• Check State Machine of Master can be changing to ‘OP’ status.
• Check State Machine of Controller can be changing to ‘OP’
status.
5.3
Operation
5.3.1 Drive Status Control
Change Drive State Machine as ‘Operation Enabled’ by setting of Control word (6040h).
• Chec
k the
Status word (6041h) whether it can be changing to ‘Operation Enabled’.
• In case of changing to ‘Fault’ status, check
the type of error by Error code (603Fh). Execute
appropriate action according to the type of error.
5.3.2 Set Mode
Set Mode of operation (6060h) according to operation mode will be used.
Information
Trial operation explains operation by Profile Position Mode.
Set Mode of operation (6060h) at 1.
• Check
the Mode of operation display (6061h) whether it has properly changed.
5.3.3 Set Operation
Set Objects according to Motion will be executed.
Information
Trial operation explains operation by Profile Position Mode.
Input 10000 at Target position (607Ah).
Input 1000 at Profile velocity (6081h).