6.6.9 Object 200Ah: Motor number
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
200Ah
0
Motor
number
U16
RO
No
No
This Object indicates number of motors currently set.
6.6.10 Object 200Ch: Reference resolution
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
200Ch
0
Motor
number
U32
RW
Yes
No
500
∼
100000
10000
This Object sets required number of Pulse to rotate 1 revolution of motor.
Information
Recommend to set same or lower value of Encoder resolution (2005h). In case of setting
higher value than Encoder resolution, certain value of Following error can be generated.
Information
This object can NOT be set while it is in
’Operation Enabled’ state. Please set after
’Operation Disable’.
Please refer to
4.1 Drive Status Control.
6.6.11 Object 200Dh: Position control gain
Index
Sub
Index
Name
Type
Access SAVE
PDO
Mapping
Value
Range
Default
Value
200Dh
0
Position
control
gain
U8
RW
Yes
No
0
∼
63
3
This function is used to control the response to the load attached to the motor after stopping
the motor. If this set value is small, the operation of stopping the motor becomes sensitive,
and the time it takes for the motor to stop is reduced. If the setting value is large, the
operation of stopping the motor becomes insensitive, and the time taken for the motor to
stop increases relatively.