32/108
4.2
Error Code
Once an Error generates, the Controller (Sense Fault signal), changes to Fault reaction active
status.
Under ‘Fault’/‘Fault reaction active’ status, types of error can be checked by Error code
(603Fh).
Table 4-5: Error codes.
Error code
External
indication
1
Status
Description
Hex/Dec
0x7500/29952
E-500
EtherCAT
Communication Error
An error occurred in EtherCAT
Communication.
0xFF01/65281
E-001
Over Current Error
The current through power
devices in inverter exceeds 4.8 A.
0xFF02/65282
E-002
Over Speed Error
Motor speed exceed 3000 rpm.
0xFF03/65283
E-003
Position Tracking
Error
Position error value is higher than
set value.
2
Following error window
(6065h).
0xFF04/65284
E-004
Over Load Error
The motor is continuously
operated more than 5 second
under a load exceeding the Max.
torque of motor.
0xFF05/65285
E-005
Over Temperature
Error
Inside temperature of drive
exceeds 85
°C.
0xFF06/65286
E-006
Over Regenerated
Voltage Error
Motor Back-EMF is higher than
limit value.
3
0xFF07/65287
E-007
Motor Connection
Error
Abnormal connection between
drive and motor.
0xFF08/65288
E-008
Encoder Connection
Error
Abnormal connection between
drive and encoder.
0xFF0A/65290
E-010
In-position Error
After operation is finished,
position error (over 1) generated
more than 3 seconds.
0xFF0C/65292
E-012
ROM Error
Error occurs in parameter storage
device (ROM).
0xFF0F/65295
E-015
Position Overflow
Error
Position error value is higher than
given value after completion of
position movement command.
4
0xFF31/65329
E-049
Drive Alarm
Generated Extra alarms generated
from drive.
0xFF32/65330
E-050
Internal
communication error
of drive
Communication error from
internal components of drive
generated (Time-out).
0xFF34/65332
E-052
Internal
communication error
of drive
Communication error from
internal components of drive
generated (CRC Failed).