Triple-IN
GmbH
© Triple-In GmbH • 27/01/2016 11:07:00
PSxxx-20 Laser Scanner User's Manual
47
47
47
47
SW hold time [ms]
The delay between counter signals can be defined by the user parameter
SW delay [ms]
The resolution of both timing parameters is about 10 ms.
Example
Example
Example
Example
The parameter setup
53; 3; SW1 function: 0=off, 1=scan sync, 2=switch, 3=counter;
56; 10; SW1 hold time [ms];
57; 20; SW1 delay [ms];
58; 0; SW1 logic: 0=normal, 1=low active;
59; 3; SW2 function: 0=off, 1=scan sync, 2=switch, 3=counter;
62; 30; SW2 hold time [ms];
63; 40; SW2 delay [ms];
64; 1; SW2 logic: 0=normal, 1=low active;
In conjunction with the counter parameters
55; 4; Temp: SW1 preset counter: setup;
61; 2; Temp: SW2 preset counter: setup;
Results in the following signal pattern:
Picture 31 Digital switching output example signal pattern