Triple-IN
GmbH
© Triple-In GmbH • 27/01/2016 11:07:00
PSxxx-20 Laser Scanner User's Manual
29
29
29
29
2.
Confirm that you have administrator permissions to install the program.
3.
The installer inspects the version information in order to use it during the
installation process.
4.
The product information (company, product name and version) is displayed
on the screen if it's found during the analysis process.
5.
Confirm installation.
A full description of the program can be found in the “of PSControlProgram User’s
manual”. The manual is part of the program distribution.
7.2
Startup Procedure
To start the system:
•
Connect the control computer to the same network of the PS Range Module.
•
Connect the power supply to the PS Range Module
•
After switching on the supply voltage the scanner runs through a self-test. All
LEDs are flashing. The firmware of the device checks important hardware
components and parameters. Commands will respond to the control computer
with a "device not ready" error.
•
The red LED is switched off after the self-test has passed successfully.
ATTENTION
ATTENTION
ATTENTION
ATTENTION
After disconnecting the sensor from power supply, you have to wait 30 seconds
before turning it back on. Otherwise capacitors not being discharged could leave
the sensor peripheral not fully reset
7.3
Serial RS232 Communication
7.3.1
Setting up the serial communication
PS Range Modules have serial RS232 interfaces to connect a control computer
with the measurement board. A second RS232 can be connected to the Ethernet
board to allow firmware updates. The standard communication settings are:
Type:
Serial input/output on RS232
Baud rate:
115.200 Baud,
8 data bit, no parity, 1 stop bit, no handshake