PSxxx-20 Laser Scanner User's Manual
50
50
50
50
Local IP: 10.0.12.34:1024
Gateway IP: 10.0.10.0:1025
13.
The parameters stored in the non-volatile memory of the sensor might be
incompatible with the new firmware version and must be updated. In this case
will the sensor request a parameter update. The firmware asks to reset all
parameters and to store the parameters in the flash. Confirm both questions
with “yes”:
- Warning: Firmware update detected; System need factory reset.
> Set all parameters to defaults (y/n)?
> Y
- Restoring control values...
- Restoring user settings...
- Restoring factory settings...
- Restoring factory user settings...
> Write changed parameters to flash (y/n)?
> Y
- Writing parameter setup file...
- Saving user settings...
- System needs to be restarted.
>
For a clean restart, finally switch the sensor off and on again.
8.2
Updating the Communication Board
The Ethernet support is implemented on a separate board inside of the laser
scanner. The communication board firmware can be updated in the same way like
the MPU firmware.
14.
Make sure that the Communication board RS232 of the serial interface
connector are connected with the serial interface of your computer.
15.
Proceed like described for the MPU board update.