52 0
Near field
suppression zone:
0=min
Defines the near field suppression zone. Each zone
extends the near field for about 0.8 m.
53 1
SW1 function:
0=off, 1=scan sync,
2=switch, 3=counter
Programs the SW1 function:
1=SW1 is closed while a scan is active
2=SW1 is closed if parameter "SW1 status" is set to 1
3=SW1 is used as a preset counter
54 0
Temp: SW1 status:
0=open 1=closed
Current logical status of the discrete output switch SW1
55 0
Temp: SW1 preset
counter: setup
Number of signals to be output if SW1 was configured
as preset counter.
56 20
SW1 hold time [ms]
"Holds" output SW1 for the given milliseconds after the
input signal is removed.
Allows the control device to ignore intermittent signal
losses.
57 20
SW1 delay [ms]
Requires a sensing event to last for at least the given
milliseconds before output SW1 is switched.
Allows the control device to ignore short sensing
events.
58 0
SW1 logic:
0=normal, 1=low
active
Defines the physical output logic: 0=SW1 is high active,
1=SW1 is low active.
59 0
SW2 function:
0=off, 1=scan sync,
2=switch, 3=counter
Programs the SW2 function:
1=SW2 is closed while a scan is active
2=SW2 is closed if parameter "SW1 status" is set to 1
3=SW2 is used as a preset counter
60 0
Temp: SW2 status:
0=open 1=closed
Current logical status of the discrete output switch SW2
61 0
Temp: SW2 preset
counter: setup
Number of signals to be output if SW2 was configured
as preset counter.
62 20
SW2 hold time [ms]
"Holds" output SW2 for the given milliseconds after the
input signal is removed.
Allows the control device to ignore intermittent signal
losses.
63 20
SW2 delay [ms]
Requires a sensing event to last for at least the given
milliseconds before output SW2 is switched.
Allows the control device to ignore short sensing
events.
64 0
SW2 logic:
0=normal, 1=low
active
Defines the physical output logic: 0=SW2 is high active,
1=SW2 is low active.
65 1
Low echo filter
If the laser spot is only partly reflected by object edges,
incorrect measuring arises. This filter removes
measurements
with very low echo signals.
66 1
High echo filter
If the laser spot is reflected by several surfaces,
incorrect measurements arise. This filter removes
measurements with very strong echo signals.
65 0
User parameter ID
used for testing
Parameter without function.
66 0
Temp: Memory write
protection, 1=locked
User parameters are stored the volatile memory.