Basic Configuration
3-29
3
•
Severity
– Specifies the degree of urgency that the message carries.
• Debugging – Sends a debugging notification. (Level 7)
• Information – Sends informatative notification only. (Level 6)
• Notice – Sends notification of a normal but significant condition, such as a cold
start. (Level 5)
• Warning – Sends notification of a warning condition such as return false, or
unexpected return. (Level 4)
• Error – Sends notification that an error conditions has occurred, such as invalid
input, or default used. (Level 3)
• Critical – Sends notification that a critical condition has occurred, such as
memory allocation, or free memory error - resource exhausted. (Level 2)
• Alert – Sends urgent notification that immediate action must be taken. (Level 1)
• Emergency – Sends an emergency notification that the system is now unusable.
(Level 0)
•
SMTP Server List
– Specifies a list of recipient SMTP servers.
•
SMTP Server
– Specifies a new SMTP server address to add to the SMTP Server
List.
•
Email Destination Address List
– Specifies a list of recipient Email Destination
Address.
•
Email Destination Address
– This command specifies SMTP servers that may
receive alert messages.
Web
– Click System, Log, SMTP. To add an IP address to the Server IP List, type
the new IP address in the Server IP Address box, and then click Add. To delete an IP
address, click the entry in the Server IP List, and then click Remove.
Figure 3-19 Enabling and Configuring SMTP
Summary of Contents for TL-SG5426 -
Page 1: ...TL SG5426 26 Port Gigabit Managed Switch Rev 1 0 0 1910010105...
Page 17: ...Contents xiv...
Page 21: ...Tables xviii...
Page 25: ...Figures xxii...
Page 42: ...Initial Configuration 2 10 2...
Page 107: ...Configuring the Switch 3 64 3 Figure 3 41 802 1X Port Configuration...
Page 486: ...Software Specifications A 4 A...