P9 ASD Installation and Operation Manual
277
Table 20. 460-Volt Chassis Standard Ratings Table.
Model
Number
VT130P9U
Typical
Motor HP
100% Output
Current
Continuous
Overload Current
120% for 60
Seconds
Input Voltage
3-Ph 50/60
±2 Hz
Output Voltage
3-Ph Variable
Frequency
4015
1.0
2.1 A
2.52 A
380 – 480 VAC
(±10%)
Input Voltage
Level (Max.)
4025
2.0
3.4 A
4.08 A
4035
3.0
4.8 A
5.76 A
4055
5.0
7.6 A
9.00 A
4080
7.5
11.0 A
13.0 A
4110
10
14.0 A
17.0 A
4160
15
21.0 A
25.0 A
4220
20
27.0 A
32.0 A
4270
25
34.0 A
41.0 A
4330
30
40.0 A
48.0 A
4400
40
52.0 A
62.0 A
4500
50
65.0 A
78.0 A
4600
60
77.0 A
92.0 A
4750
75
96.0 A
115 A
410K
100
124 A
149 A
412K
125
156 A
187 A
415K
150
180 A
216 A
420K
200
240 A
288 A
425K
250
302 A
362 A
430K
300
361 A
433 A
435K
350
414 A
497 A
440K
400
477 A
572 A
Summary of Contents for P9