Machine Faults
5
2
3
2
1
Faults
#11
Clear System Faults
--
3
2
.
6
Ago
4
3
g339627
Figure 10
1.
Left/right button
4.
Fault items
2.
Down button
5.
Fault menu
3.
Menu/back button
The faults screen (
) will list all the machine electrical faults that have
occurred since the faults were last cleared from the InfoCenter. The faults will be
identified by a number and when the fault occurred. The faults that might occur
on the eFlex machine are listed in the
Fault Table (page 3–5)
.
The InfoCenter fault log can be cleared by selecting the clear system faults
menu item. The cleared faults will be removed from the InfoCenter but will be
retained in the TEC memory.
If a fault occurs during machine use, there may be a change in machine
functionality due to the fault. Should there be machine operation issues due to
a fault, a first step to remedy the issue would be to move the traction bail to
the NEUTRAL position, turn the key switch to the O
FF
position, and allow all
the machine functions to stop. Then, attempt to restart the machine to see if
operation has returned to normal. Some faults will be reset during the restart
and will then allow normal function. If a fault continues to occur, further system
evaluation, and possible component repair or replacement will be necessary.
To return to the main menu screen from the faults screen, press the menu/back
button (as indicated by the
at the bottom of the screen).
Fault Table
Fault
Number
Fault Title
Controller
Affected
Fault Condition/Circuit
Description
Additional
Notes
Service Actions
1
Internal
TEC Fault
Primary
The 13.3 V regulator on
the TEC is not able to
maintain regulation at an
acceptable voltage level.
This is an
onboard power
supply for the
TEC.
1.
Reboot the machine.
2.
Disconnect and reconnect the
battery.
3.
Look for short circuits in the
harness.
4.
Replace the TEC.
2
12Vdc
Supply
Fault
Primary
The 12 V regulator on
the TEC cannot maintain
regulation at an acceptable
voltage level.
Most likely there is a short circuit
on the 12 V supply line that powers
the InfoCenter and the Slow-in-turn
switch.
Greensmaster
®
eFlex 1021
Page 3–5
Troubleshooting: Machine Faults
20248SL Rev C
Summary of Contents for 04861
Page 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Page 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Page 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Page 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Page 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Page 234: ......