Fuses
g338648
Figure 48
1.
Battery cover
2.
Washer head bolt (4 each)
A group of fuses are used to protect the 12 VDC and 48 VDC systems and
are located under the battery cover.
Accessing the Fuse
1. Ensure that the cutting-unit-drive lever is in the D
ISENGAGE
position, park the
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
FF
, and remove the key; refer to
the
Operator's Manual
.
2. Disconnect the battery pack; refer to
Disconnecting and Connecting the
Lithium Battery Pack (page 5–3)
.
3. Remove the 4 bolts that secures the battery cover to the battery mount; refer
to
. Remove the battery cover from the battery mount.
Fuse Identification and Function
g338649
Figure 49
1.
Fuse F1-1 (30 A)
3.
Fuse F1-3 (3 A)
2.
Fuse F1-2 (3 A)
4.
Fuse F1-4 (open)
Refer to
to identify each individual fuse and its correct amperage. The
fuses for the Greensmaster eFlex machines have the following functions:
Fuse F1-1 (30 A): Protects main power supply circuits.
Fuse F1-2 (3 A): Protects logic power supply circuits.
Fuse F1-3 (3 A): Protects optional LED work light circuit.
Electrical System: Testing the Electrical Components
Page 5–22
Greensmaster
®
eFlex 1021
20248SL Rev C
Summary of Contents for 04861
Page 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Page 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Page 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Page 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Page 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Page 234: ......