Bedknife
Removing the Bedknife
g227001
Figure 103
1.
Bedknife screw (13 used)
3.
Bedbar
2.
Bedknife
1.
Remove the bedbar from the cutting unit; refer to
(page 7–7)
.
2.
Using a socket wrench and the bedknife screw tool, remove screws that
secure the bedknife to the bedbar, and remove the bedknife; refer to
.
IMPORTANT
Discard the old bedknife screws.
3. Refer to
Grinding the Bedknife (page 7–14)
for additional information.
Installing the Bedknife
1.
Use a scraper to remove all rust, scale, and corrosion from the bedbar
surface under the bedknife. Lightly oil the bedbar surface before installing
the bedknife.
2.
Make sure that screw threads in bedbar (5/16-18UNC-2A) are clean.
IMPORTANT
Use new bedknife screws when installing the bedknife.
3. Assemble the bedknife to bedbar using new bedknife screws. Apply
anti-seize lubricant to the threads of new screws. Do not apply anti-seize
lubricant to the taper of the screw heads
4. Install all screws but do not tighten.
IMPORTANT
Do not use an impact wrench to tighten screws into the bedbar.
DPA Cutting Units: Service and Repairs
Page 7–12
Greensmaster
®
eFlex 1021
20248SL Rev C
Summary of Contents for 04861
Page 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Page 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Page 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Page 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Page 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Page 234: ......