Removing the Lithium-Ion Battery (continued)
g339409
Figure 74
1.
Negative (-) terminal
4.
Washer
2.
Lithium-ion battery
5.
Lock washer
3.
Positive (+) terminal
6.
Nut
1. Ensure that the cutting-unit-drive lever is in the D
ISENGAGE
position, park the
machine on a level surface, release the clutch bail, engage the service and
parking brake, rotate the key switch to O
FF
, and remove the key; refer to
the
Operator's Manual
.
2. Disconnect the battery pack; refer to
Disconnecting and Connecting the
Lithium Battery Pack (page 5–3)
.
3. Remove the four bolts that secures the battery cover to the battery mount.
Remove the battery cover from the machine.
4. Label and disconnect the negative (-) battery cable, positive (+) battery cable,
and battery interface harness from the lithium-ion battery; refer to
g339388
Figure 75
1.
Bolt (4 each)
4.
Battery mount
2.
Washer (4 each)
5.
Nut (4 each)
3.
Lithium-ion battery
5. Remove the four nuts (item 5 in
), bolts (1) and washers (2) that
secures the battery to the battery mount.
Greensmaster
®
eFlex 1021
Page 5–53
Electrical System: Service and Repairs
20248SL Rev C
Summary of Contents for 04861
Page 1: ...Form No 20248SL Rev C Greensmaster eFlex 1021 Model 04861...
Page 5: ...NOTES Greensmaster eFlex 1021 Page 5 NOTES 20248SL Rev C...
Page 6: ...NOTES Page 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 8: ...g340146 Figure 1 Preface Page 8 Greensmaster eFlex 1021 20248SL Rev C...
Page 16: ...Safety Safety and Instructional Decals Page 1 6 Greensmaster eFlex 1021 20248SL Rev C...
Page 198: ...DPA Cutting Units Service and Repairs Page 7 32 Greensmaster eFlex 1021 20248SL Rev C...
Page 228: ...Universal Groomer Optional Service and Repairs Page 8 30 Greensmaster eFlex 1021 20248SL Rev C...
Page 234: ......