TMP High Performance Vector Control Inverter User Manual
66
P2.04 ACC time4
Setting arrange
:
0.1
~
3600s
P2.05 ACC time4
Setting arrange
:
0.1
~
3600s
Four Acc/Dec times are defined as following:
Phases of Acc/Dec time
1
2
3
4
Terminal state
X4
OFF
ON
OFF
ON
X5
OFF
OFF
ON
ON
As shown in the table above, in normal operation condition, Acc/Dec time 1 is the default
setting (both terminals X4, X5 are OFF, and Acc/Dec time 1 and 2 are defined by terminal X4 and
X5 respectively).
P2.06 Jog Acc time 1
Setting range: 0.1
~
20.0s
P2.07 Jog Dec time 1
Setting range: 0.1
~
20.0s
P2.08 Jog frequency
Setting range: 0, 1~60.00Hz
P2.06~P2.08 define the jog running parameters, which is shown in Fig. 8-7.
In Fig. 6-7, f1 is Jog running frequency (P2.08), t1 is Jog Acc time (P2.06), t3 is Jog Dec
time (P2.07), and t2 is the Jog running time.
Jog running command can be issued through panel, control terminal or host computer.
Fig. 6-7 Jog running parameters
P2.09 Multi-frequency 1
Setting range: 0~400.0Hz
P2.10 Multi-frequency 2
Setting range: 0~400.0Hz
P2.11 Multi-frequency 3
Setting range: 0~400.0Hz
P2.12 Multi-frequency 4
Setting range: 0~400.0Hz
P2.13 Multi-frequency 5
Setting range: 0~400.0Hz
P2.14 Multi-frequency 6
Setting range: 0~400.0Hz
P2.15 Multi-frequency 7
Setting range: 0~400.0Hz
P2.16 Multi-frequency 8
Setting range: 0~400.0Hz
P2.17 Multi-frequency 9
Setting range: 0~400.0Hz
P2.18 Multi-frequency 10
Setting range: 0~400.0Hz
P2.19 Multi-frequency 11
Setting range: 0~400.0Hz
P2.20 Multi-frequency 12
Setting range: 0~400.0Hz
P2.21 Multi-frequency 13
Setting range: 0~400.0Hz
P2.22 Multi-frequency 14
Setting range: 0~400.0Hz
P2.23 Multi-frequency 15
Setting range: 0~400.0Hz