TMP High Performance Vector Control Inverter User Manual
19
2.3.3
Removal
and
Mounting
of
Covers
of
TMP
−011G-4/015P-4
~
TMP
−075G-4/090P-4
and Above Power Class Inverter with Sheet-metal Enclosure
Removal of operation panel
Please refer to 2.3.1 Removal and mounting of operation panel.
Removal of cover
Remove the mounting screws on the lower part of the cover, lift the cover in direction 1 as shown in
Fig.2
−9, and then take out the cover in direction 2.
Mounting of cover
After the wiring of the main circuit terminals and control circuit terminals, cramp the cover in
direction 1 as shown in Fig.2
−10, press down the cover in direction 2 and then tighten the cover
screws.
Fig.2−9 Removal of cover Fig.2−10 Mounting of cover
Mounting of operation panel
Please refer to 2.3.1 Removal and mounting of operation panel.
Note:
Do not directly mount the cover with operation panel on the inverter, otherwise, the operation panel will
have poor contact.
2.3.4 O
pen and Close of Doors of TMP
−090G-4 and Above Power Class Inverter with
Sheet-metal Enclosure
Opening of the door
Press the latch following direction 1 in Fig.2
−11 and open the door following direction 2.
Removal of operation panel