TMP High Performance Vector Control Inverter User Manual
39
10:Panel potentiometer setting (0~5V)
P0.04
Main Frequency gain
0.000-9.999
1.000
4
+
P0.05
Zero
frequency
source
of
multi-speed mode
0
:
Digital frequency of
P0.11
1
:
External analog signal: AI1
2
:
External analog signal: AI2
3: Panel potentiometer setting (0~5V)
0
5
+
P0.06
Auxiliary
frequency
source
0
:
External analog signal: AI1(0~10V)
1
:
External analog signal: AI2(0~10V) or
0~20mA
2
:
External analog signal:AI1(0~10V)
(
+/-
polarity
)
3
:
External analog signal: AI2
AI2(0~10V) or 0~20mA
(
+/- polarity
)
4
:
pid
0
6
+
P0.07
Auxiliary
frequency
range selection
0
:
Maximum output frequency
1
:
Main frequency
0
7
+
P0.08
Auxiliary
frequency
range
0-100%
100
8
+
P0.09
Setting Frequency
selection
0
:
Main frequency
1
:
Auxiliary
frequency
2
:
Main fre Auxiliary
frequency
3
:
Main frequency - Auxiliary
frequency
4
:
switch between Main frequency and
Auxiliary
frequency
5
:
switch between Main frequency and
(
Main
fre Auxiliary
frequency
)
6
:
switch between Main frequency and
(
Main
frequency - Auxiliary
frequency
)
7
:
MAX
(
Main frequency
,
Auxiliary
frequency
)
8
:
MIN
(
Main frequency
,
Auxiliary
frequency
)
9
:
Traverse operation
0
9
+
P0.10
up/down setting store
selection
0
:
Store
1
:
Not Store
0
10
#