TMP High Performance Vector Control Inverter User Manual
31
Chapter 4 Using Instructions of Operation Panel
4.1 Introduction to Operation Panel
Shuttle type operation pane
(
TMP
−DP01
)
Analog type operation pane
(
TMP
−DP02
)
Fig. 4−1 Display unit of operation panel
4.2 Descriptions of Indicators
Symbol of
Indicator
Name
Meanings
Color
Hz
Frequency indicator
On: Current display parameter is running
frequency
red
A
Current indicator
On: Current display parameter is current
red
V
Voltage indicator
On: Current display parameter is voltage
red
Hz+A
Rotating speed indicator
On: Current display parameter is rotating
speed
red
A+V
Time indicator
On: Current display parameter is time
red
Hz+A+V
% indicator
On: Current display parameter is rotating
speed
red
No unit indicator
Off: Current display parameter is no unit
−
L/R
Running command
reference mode indicator
On: Running command is given via operation
panel
Off: Running command is given via terminals
Flash: Running command is given via host
computer
red
RUN
Running status indicator
On: Inverter is running
Off: Inverter has stopped
Flash: Inverter is stopping
green
F/R
Run forward indicator
On: In stop status, inverter has run forward
command;
In running status, inverter is running
forward
Flash: Changing from running forward to
running reverse
red
TRIP
Faule/Alarm
indicator
ON:Normal condition
Off:Fault condition
Flash:Alarm
red