Chapter 3 ’Web Browser Interface’ — Workflow Library Content Parameters
148
ViBE VS7000
User Manual
Figure 3-120
shows the parameters set for the
Selector
tool.
Figure 3-120. Selector properties
In our example, we create a parameter called
Use TS file
to be used in the
condition and we limit the possible values to
true
or
false
.
Then we set the condition as follows:
Input #1, i.e. the TS over IP input, must be used if the
Use TS file
parameter is set to
false
.
Input #2, i.e. the TS file input, must be used if the
Use TS file
parameter is not set to
false
(i.e.
true
).