Cool Mode
The refrigerant flow in Cool Mode is a
conventional refrigeration cycle. High pressure
refrigerant vapor leaves the compressor and flows
through the open CIS to the condenser where the
refrigerant releases heat and condenses into high
pressure liquid. The liquid refrigerant flows
through the condenser check valve, receiver tank,
drier, heat exchanger, and the expansion valve
into the evaporator. There, liquid refrigerant
absorbs heat as it evaporates into low pressure
vapor. The refrigerant returns to the compressor
through the heat exchanger, and accumulator.
Solenoid and Check Valves
1. Condenser Inlet Solenoid (CIS)-Open/
De-energized
2. Liquid Injection Solenoid (LIS)-Closed/
De-energized but the microprocessor will
open it if necessary to control compressor
temperature.
3. Condenser Check Valve-Open
4. Receiver Tank Pressure Check Valve-Closed
5. Purge Valve (PV)-Closed/De-energized
6. Purge Check Valve-Closed
7. Hot Gas Solenoid (HGS)-Closed/
De-energized
Figure 7: Cool Mode
1
2
3
4
5
6
7
Summary of Contents for UT-1200
Page 10: ...Table of Contents 10...
Page 20: ...Safety Precautions 20...
Page 76: ...Operating Instructions for Premium HMI Control Panel 76...
Page 88: ...Electrical Maintenance 88...
Page 98: ...Engine Maintenance 98 Figure 167 Fuel Components...
Page 142: ...Refrigeration Service Procedures 142...
Page 148: ...Clutch Maintenance 148...
Page 150: ...Structural Maintenance 150...
Page 162: ...Wiring and Schematic Diagrams Index 162...
Page 163: ...163 Schematic Diagram Page 1 of 2...
Page 164: ...164 Schematic Diagram Page 2 of 2...
Page 165: ...165 Wiring Diagram Page 1 of 5...
Page 166: ...166 Wiring Diagram Page 2 of 5...
Page 167: ...167 Wiring Diagram Page 3 of 5...
Page 168: ...168 Wiring Diagram Page 4 of 5...
Page 169: ...169 Wiring Diagram Page 5 of 5...