Electrical Maintenance
87
Overload Relay Replacement
When the overload relay is replaced, the new
overload relay must be set up to open at the
correct amperage and reset automatically. See the
following procedure to set up a new overload
relay.
1. Open the clear plastic cover.
2. Use a small screwdriver to set the opening
amperage. See “Electric Motor and Overload
Relay” in the “Specifications” chapter for the
correct overload relay setting.
3. Use a small screwdriver to remove the tab
between the “H” and the “A” to access the
switch used to set the overload relay to reset
automatically.
4. Move the slide switch down until it clicks into
place at the bottom of the slot (from which the
tab marked “H” was removed). This sets the
overload relay to reset automatically.
The new overload relay is now set up correctly.
Note which wires go to which terminals when
removing the old overload relay so the wires are
connected correctly when the new overload relay
is installed.
1.
Lift Here to Open Cover
Figure 154: Open Cover
1
1.
Set Opening Amperage
2.
Remove Tab Between “H” and “A”
Figure 155: Set Amperage and Remove Tab
1.
Switch Clicks into Place at Bottom of Slot
Figure 156: Move Switch Down
2
1
1
Summary of Contents for UT-1200
Page 10: ...Table of Contents 10...
Page 20: ...Safety Precautions 20...
Page 76: ...Operating Instructions for Premium HMI Control Panel 76...
Page 88: ...Electrical Maintenance 88...
Page 98: ...Engine Maintenance 98 Figure 167 Fuel Components...
Page 142: ...Refrigeration Service Procedures 142...
Page 148: ...Clutch Maintenance 148...
Page 150: ...Structural Maintenance 150...
Page 162: ...Wiring and Schematic Diagrams Index 162...
Page 163: ...163 Schematic Diagram Page 1 of 2...
Page 164: ...164 Schematic Diagram Page 2 of 2...
Page 165: ...165 Wiring Diagram Page 1 of 5...
Page 166: ...166 Wiring Diagram Page 2 of 5...
Page 167: ...167 Wiring Diagram Page 3 of 5...
Page 168: ...168 Wiring Diagram Page 4 of 5...
Page 169: ...169 Wiring Diagram Page 5 of 5...