27
Unit Description
General Description
The UT-1200X is a microprocessor based
transport temperature control system, which
utilizes the SR-3 Truck HMI microcontroller to
manage system functions.
The unit is a two-piece under-mount refrigeration
unit designed for truck applications. The
condenser unit mounts underneath the truck and
the evaporator mounts inside the truck body. Two
different evaporators are used: the UTSE, and the
Spectrum S-3.
Engine power for the UT-1200X is provided by
the TK376, a three cylinder, special clean and
silent diesel engine rated at 19.6 continuous
horsepower (14.6 kW) at 2425 RPM. A belt drive
system transfers energy to the compressor, unit
fans and alternator. A centrifugal clutch on the
diesel engine isolates the engine during electric
standby operation. The clutch engages fully at 600
± 100 rpm on engine operation.
Unit Features
•
Microprocessor Controller, SR-3 Truck
•
Alarm Code Display
•
Battery Voltage Display
•
Continuous System Monitoring
•
Coolant Temperature Display
•
CYCLE-SENTRY
TM
Start/Stop Controls
•
Engine and Electric (Model 50) Hour
Display
•
In-Cab Remote
•
Smart Defrost
•
Symbolic Controller Interface
•
Unit Self Check-pretripping
•
Air Cleaner, Dry Type
•
Alternator, 65 amp for UT-800, 120 Amp for
UT-1200
•
Automatic Phase Correction (Model 50)
•
Bypass Oil Filter
•
Coolant Expansion Tank
•
Corrosion Resistant Protection
•
Diesel/Electric Autoswitching
•
Economy Mode
•
Fahrenheit and Celsius Scales
•
Fuel Filter, Spin On
•
Oil Filter, Full Flow
•
R-404A Chlorine-free Refrigerant
•
Scroll Compressor
•
Stainless Steel Condenser and Evaporator
Hardware
•
TK376U Diesel Engine
Unit Options
•
DAS (Data Acquisition System)
•
Door Switch
•
Evaporator Side Screens
•
Scissors Field Installation Kit
•
Synthetic Oil
•
Battery Box Kit
•
Remote Body-Mount Box Kit
•
Premium HMI Control Panel
•
Telematics
Standard HMI Control Panel
The Standard HMI Control Panel
(Human/Machine Interface) is used to operate the
unit and display unit information. The Control
Panel is typically located in the vehicle driver's
compartment and communicates with the base
controller using a connection on the interface
board.
Figure 1: Standard HMI Control Panel
Summary of Contents for UT-1200
Page 10: ...Table of Contents 10...
Page 20: ...Safety Precautions 20...
Page 76: ...Operating Instructions for Premium HMI Control Panel 76...
Page 88: ...Electrical Maintenance 88...
Page 98: ...Engine Maintenance 98 Figure 167 Fuel Components...
Page 142: ...Refrigeration Service Procedures 142...
Page 148: ...Clutch Maintenance 148...
Page 150: ...Structural Maintenance 150...
Page 162: ...Wiring and Schematic Diagrams Index 162...
Page 163: ...163 Schematic Diagram Page 1 of 2...
Page 164: ...164 Schematic Diagram Page 2 of 2...
Page 165: ...165 Wiring Diagram Page 1 of 5...
Page 166: ...166 Wiring Diagram Page 2 of 5...
Page 167: ...167 Wiring Diagram Page 3 of 5...
Page 168: ...168 Wiring Diagram Page 4 of 5...
Page 169: ...169 Wiring Diagram Page 5 of 5...