Operating Instructions for Premium HMI Control Panel
67
Figure 103: Menu Key
The Language Menu or Alarm Menu will appear.
Press the NEXT key as required to display the
Hourmeter Menu. When the Hourmeter Menu is
shown press the SELECT key. The Hourmeter
Display will appear.
Figure 104: Hourmeter Display
Press the NEXT or PREVIOUS key to scroll
through the enabled hourmeters.
Figure 105: Scroll Through Hourmeters
Hourmeter names and definitions are shown in the
table below in the order they appear. Only
hourmeters enabled in the Guarded Access Menu
will be shown. To return to the Standard Display,
press the EXIT key.
Hourmeter Names and Definitions
Total Hours:
Total number of hours the unit has
been turned on (protection hours).
Total Run Time Hours:
Total number of hours the
unit has run in both diesel and electric mode.
Engine Hours:
Total number of hours the unit has
run in diesel mode.
Electric Run Hours:
Total number of hours the unit
has run in electric mode.
Total Run Reminder 1:
User Programmable - The
number of hours before a Total Unit Run Time
Maintenance Reminder 1 occurs.
Total Run Reminder 2:
User Programmable - The
number of hours before a Total Unit Run Time
Maintenance Reminder 2 occurs.
Controller Power On:
Total hours the controller
and HMI control panel have been turned on.
Pretrip Reminder :
User Programmable - number
of hours before a Pretrip Reminder occurs.
Engine Reminder 1:
User Programmable - The
number of hours before an Engine Run Time
Maintenance Reminder 1 occurs.
Engine Reminder 2:
User Programmable - The
number of hours before an Engine Run Time
Maintenance Reminder 2 occurs.
Electric Reminder 1:
User Programmable - The
number of hours before an Electric Run Time
Maintenance Reminder 1 occurs.
Electric Reminder 2:
User Programmable - The
number of hours before an Electric Run Time
Maintenance Reminder 2 occurs.
IMPORTANT: If a programmable hourmeter is
not enabled or the view for that hourmeter is not
turned on it will not appear in the display
sequence.
Mode
Various operating modes can be selected using the
Mode menu. Not all modes may be available,
depending on settings of other programmable
features. The following modes may be available.
Turn CYCLE-SENTRY On or Off
CYCLE-SENTRY Mode can be turned On or Off.
If CYCLE-SENTRY Mode is turned Off then unit
will run in Continuous mode.
Keypad Lockout
If enabled in Guarded Access, the keypad can be
locked to prevent unauthorized use. If the keypad
is locked only the ON and OFF keys function. The
keypad will remain locked even if the unit is
turned Off and back on. If Keypad Lockout is
active, press and hold any soft key for 5 seconds
to deactivate the feature.
Summary of Contents for UT-1200
Page 10: ...Table of Contents 10...
Page 20: ...Safety Precautions 20...
Page 76: ...Operating Instructions for Premium HMI Control Panel 76...
Page 88: ...Electrical Maintenance 88...
Page 98: ...Engine Maintenance 98 Figure 167 Fuel Components...
Page 142: ...Refrigeration Service Procedures 142...
Page 148: ...Clutch Maintenance 148...
Page 150: ...Structural Maintenance 150...
Page 162: ...Wiring and Schematic Diagrams Index 162...
Page 163: ...163 Schematic Diagram Page 1 of 2...
Page 164: ...164 Schematic Diagram Page 2 of 2...
Page 165: ...165 Wiring Diagram Page 1 of 5...
Page 166: ...166 Wiring Diagram Page 2 of 5...
Page 167: ...167 Wiring Diagram Page 3 of 5...
Page 168: ...168 Wiring Diagram Page 4 of 5...
Page 169: ...169 Wiring Diagram Page 5 of 5...