Operating Instructions for Premium HMI Control Panel
58
Figure 73: Defrost Display
Terminating a Defrost Cycle
The defrost cycle terminates automatically when
the coil temperature is greater than or equal to 52
F (11 C) or the defrost timer expires. Defrost can
also be terminated by turning the unit off and back
on.
Selecting High Speed Lockout
Mode (If Enabled)
High speed operation can be locked out in noise
sensitive areas if required.
NOTE: High Speed Lockout Enable must be set
to [Enabled] in the Guarded
Access/Programmable Features Menu or this
feature will not be available.
IMPORTANT: HIGH SPEED LOCKOUT
TIMEOUT: If High Speed Lockout Mode is
selected, the High Speed Inhibit Timeout feature
may be set to return the unit to normal operation
after a set time period has expired. This prevents
extended operation with high speed operation
locked out. The time period may be from 15
minutes to 2 hours. If the time period is set and is
exceeded the unit will return to normal
operation, with high speed operation allowed. If
this occurs, the message HIGH SPEED
LOCKOUT ACTIVE at the top of the display will
disappear. If necessary to return to High Speed
Lockout Mode, press the High Speed Lockout
Key again.
The High Speed Lockout Key is a toggle. If high
speed is currently allowed, then pressing the High
Speed Lockout Key will disable high speed
operation. Pressing the High Speed Lockout Key
again will allow high speed operation. To change
the setting, press the High Speed Lockout key as
shown below.
Figure 74: High Speed Lockout Key
The display will briefly show [PROGRAMMING
HIGH SPEED LOCKOUT - PLEASE WAIT].
Figure 75: PROGRAMMING HIGH SPEED
LOCKOUT - PLEASE WAIT
The change is confirmed by briefly displaying
[HIGH SPEED LOCKOUT ACTIVE] or [HIGH
SPEED LOCKOUT INACTIVE].
Figure 76: High Speed Lockout Display
The display will then return to the Standard
Display. If High Speed Lockout is turned on, the
message HIGH SPEED LOCKOUT ACTIVE will
be shown at the top of the display.
Figure 77: Standard Display, High Speed Lockout
Active
Pressing the High Speed Lockout key again will
turn the feature off.
Summary of Contents for UT-1200
Page 10: ...Table of Contents 10...
Page 20: ...Safety Precautions 20...
Page 76: ...Operating Instructions for Premium HMI Control Panel 76...
Page 88: ...Electrical Maintenance 88...
Page 98: ...Engine Maintenance 98 Figure 167 Fuel Components...
Page 142: ...Refrigeration Service Procedures 142...
Page 148: ...Clutch Maintenance 148...
Page 150: ...Structural Maintenance 150...
Page 162: ...Wiring and Schematic Diagrams Index 162...
Page 163: ...163 Schematic Diagram Page 1 of 2...
Page 164: ...164 Schematic Diagram Page 2 of 2...
Page 165: ...165 Wiring Diagram Page 1 of 5...
Page 166: ...166 Wiring Diagram Page 2 of 5...
Page 167: ...167 Wiring Diagram Page 3 of 5...
Page 168: ...168 Wiring Diagram Page 4 of 5...
Page 169: ...169 Wiring Diagram Page 5 of 5...